Typically, what system would we recommend for use in the EfW sector?
The CEMs market is mature and there are a good selection of products available.
The MCA10 is our core analyser for the EfW sector. It has some of the lowest available ranges and uncertainties and is the technical and reliability performance equal of any available alternative system.
Additionally, the MCA10 should be noted for:
- 6 monthly maintenance intervals on all components – including TOC
- Integrated manifold enabling expansion / addition of further systems should they be required in the future
| Manufacturer | Dr Foedisch | Leading Alternative 1 | Leading Alternative 2 |
|---|---|---|---|
| Analyser | MCA 10 | FTIR | NDIR |
| CO | 0-75 | 0-75 | 0-75 |
| NO | 0-80 | 0-200 | 0-150 |
| NO2 | 0-50 | 0-100 | 0-50 |
| N20 | 0-50 | 0-50 | 0-100 |
| SO2 | 0-75 | 0-75 | 0-75 |
| HCL | 0-15 | 0-15 | 0-15 |
| NH3 | 0-10 | 0-10 | 0-10 |
| CH4 | 0-50 | 0-50 | 0-50 |
| CO2 | 0-25 | 0-25 | 0-25 |
| O2 | 0-25 | 0-21 | 0-25 |
| H2O | 0-40 | 0-40 | 0-40 |
| TOC | 0-15 | 0-15 | 0-15 |
| Technology | NDIR – Hot-wet | NDIR – Hot-wet | NDIR – Hot-wet |
| Service Frequency |
All Components: 6 Months |
6 Months, Except: O2 – 4 Weeks, TOC – 2 Months, CO2/NH3 – 3 Months |
All Components: 3 Months |
| Measurement Uncertainty | MCERTS 15267-3 Requirements and recommended performance achieved – Without Exception | MCERTS 15267-*2 Requirements and recommended performance achieved – With Exception for CO, HF, HCL and NO2. |
MCERTS 15267- Requirements and recommended performance achieved – Without Exception |
What are the recent and impending changes in this sector?
The most recent changes, include those introduced by the BAT / BREF – lowering ELV’s for all existing and new plants.
EA guidance is also requesting CO2 and N2O components to be added to QAL 2 and QAL 3 routines. This is a request at the moment but we expect this to become a mandatory requirement in the future.
Flow is now also required to be included as part of the QAL 2 testing.
Further to this, continuous Mercury and Dioxin measurements may be required for some plants!
MCA 10
- Continuous extractive measurement of up to 12 infrared gas components
- Hot-wet measurement
- Class leading certified ranges
- 6-month service interval
- Simple design and operating system
- Remote diagnosis
- First class price/performance ratio
View the MCA 10 C Product Page
FMD 09
- Compact device consisting of probe and operating unit no separate operating device necessary
- Local diagnosis of system state by integrated graphic display
- Real-time display with line diagram
- Readout of volume flow at standard reference conditions possible
- Easy mounting
- Very low maintenance requirement
- Absolute pressure measurement (optional)
View the FMD 09 Product Page
PFM 20
- Long life span
- Low ownership costs
- QAL 1 approved
- MCERTS approved
- Efficient and robust design
- Low maintenance requirements
- Automatic zero/span point checks
- Customisable probe lengths
View the PFM 20 Product Page